American Dryer Corp. ML-145 Installation Manual

Browse online or download Installation Manual for Electric laundry dryers American Dryer Corp. ML-145. American Dryer Corp. ML-145 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ADC Part No. 112247
ML-145
Installation Manual
For replacement parts, contact the reseller from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
E-mail: techsupport@amdry.com
012097MM/tf
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez..
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
Page view 0
1 2 3 4 5 6 ... 52 53

Summary of Contents

Page 1 - Installation Manual

ADC Part No. 112247ML-145Installation ManualFor replacement parts, contact the reseller from which the dryerwas purchased orAmerican Dryer Corporation

Page 2 - Important

6IMPORTANT: Steam dryers must be provided with a clean, dry, regulated 80 PSI +/- 10 PSI(552 kPa +/- 69 kPa) air supply.NOTE: ADC reserves the right t

Page 3 - FOR YOUR SAFETY

7NOTE: ADC reserves the right to make changes in specifications at any time without notice orobligation.SPECIFICATIONSML-145

Page 4

8B. COMPONENT IDENTIFICATION1. Dryer Front ViewIllus. No. Description1 Microprocessor Control/Keyboard (touch pad) Panel Assembly (controls)2 Control

Page 5 - Table of Contents

92. Dryer Rear ViewIllus. No. Description1 Basket (tumbler) Drive Motor Assembly2 Blower (impellor/fan) Motor Mount Assembly3 Idler Bearing Mount Ass

Page 6

10SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Page 7 - SECTION I

11B. UNPACKING/SETTING UPRemove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.IMPORTANT: Dryer must be t

Page 8 - B. SAFETY PRECAUTIONS

12IMPORTANT: The dryer must be transported and handled in an upright position at ALL times.a. To Reconnect V-belts1) Remove hardware holding the back

Page 9

13C. DRYER ENCLOSURE REQUIREMENTSEven though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer bepositioned

Page 10 - SECTION II

14IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.Make-up air that is contaminated by dry cleaning solvent fu

Page 11 - SPECIFICATIONS

15E. EXHAUST REQUIREMENTS1. General Exhaust Duct Work InformationExhaust duct work should be designed and installed by a qualified professional. Imp

Page 12 - B. COMPONENT IDENTIFICATION

Retain This Manual In A Safe Place For Future ReferenceAmerican Dryer Corporation products embody advanced concepts in engineering, design, and safety

Page 13

16IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must notexceed 0.3 inches of water column (W.C.) - 0.74 mb.IMPORTANT: W

Page 14 - SECTION III

17a. Ducting (Horizontal and Vertical)1) For single dryer horizontal ducting the minimum duct size is 16-inches (40.64 cm) in diameter, theduct run sh

Page 15 - B. UNPACKING/SETTING UP

18b. Outside Duct Work Protection1) To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downwardshould be installed

Page 16

19The main duct may be any shape or cross-sectional area, so long as the minimum cross section area isprovided. The illustrations on page 20 show the

Page 18

21F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and com

Page 19 - E. EXHAUST REQUIREMENTS

222.Electrical Service SpecificationsIMPORTANT: The dryer must be connected to the electric supply shown on the data label that isaffixed to the left

Page 20

233. Electrical ConnectionsNOTE: A wire diagram is located in the front electrical control box for connection data.The only electrical input connecti

Page 21

244.GroundingGrounding (earth) connections must be provided and installed in accordance with state and local codes. Inthe absence of these codes, gro

Page 22

25G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing instal

Page 23

IMPORTANTYOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GASSUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS AREREMOVED FROM THE MAC

Page 24

26b. Gas Connections:Inlet connection-------------------------------------- 1-1/4” F.P.T.Inlet supply size-------------------------------------- 1-1/

Page 25 - F. ELECTRICAL INFORMATION

273.Piping/ConnectionsALL components/materials must conform to National Gas Code Specifications, or in CANADA, theCanadian Installation Codes (for Gen

Page 26 - MLS-145 (Steam)

28It is important that gas pressure regulators meet applicable pressure requirements and that gas meters berated for the total amount of ALL the appli

Page 27

29H. STEAM INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing inst

Page 28

30c. Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause thesteam coil connections to crack if the

Page 29 - G. GAS INFORMATION

314.Steam Damper Air System ConnectionsThe MLS-145 is manufactured with a pneumatic (piston) damper system which requires an external supplyof compres

Page 30 - Natural Liquid Propane (L.P.)

326.Steam Damper Air Piston (Flow Control) Operation AdjustmentAlthough the steam damper operation was tested and adjusted prior to shipping at 80 PSI

Page 31

33I. PREPARATION FOR OPERATION/START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL “CAUTION,” “WARNING,”

Page 32

34J. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performe

Page 33 - OPERATING STEAM PRESSURE

35IMPORTANT: The fan (impellor/blower) shaft rotation must be verified by removing the left sideaccess panel. When looking at the fan (impellor/blowe

Page 34

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY or FIRE COULD RESULT.IMPOR

Page 35 - Maximum Supply 90 PSI

368. A reversing basket (tumbler) should never be operated with less than a 100 pound (45.35 kg) load (dryweight). The size of the load will affect t

Page 36

37L. COMPRESSED AIR REQUIREMENTSThe model ML-145 dryer requires an external supply of compressed air of 2.5 cfm at 80 PSI (0.07 cmm at 552kPa). For

Page 37

38SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Page 38 - J. PREOPERATIONAL TESTS

39SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARD(S)1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the ba

Page 39

402. Each part must be tagged with the following information:a.Model number and serial number of the dryer from which part was removed.b. Nature of fa

Page 40 - K. SHUT DOWN INSTRUCTIONS

41SECTION VIROUTINE MAINTENANCEA. CLEANINGA program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from

Page 41

42STEAM DRYERSClean the steam coil fins. Compressed air and a vacuum cleaner with brush attachment are suggested.NOTE: When cleaning steam coil fins,

Page 42 - SECTION IV

43B. ADJUSTMENTS7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTERInspect bolts, nuts, screws, (bearing setscrews), nonpermanent gas connections

Page 43 - SECTION V

44SECTION VIIDATA LABEL LOCATION/INFORMATIONA. DATA LABELWhen contacting American Dryer Corporation, certain information is required to insure prope

Page 44

45THE DATA LABEL1. MODEL NUMBERThe model number is an ADC number which describes the size of the dryer and thetype of heat (gas, electric, or steam).2

Page 45 - SECTION VI

Table of ContentsSECTION IIMPORTANT INFORMATION...3A. Receiving and Handl

Page 46

46SECTION VIIIPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. Microprocessor Controller (computer) Boarda. Upon completing installation of t

Page 47 - C. LUBRICATION

471) “FAN” (Blower) light emitting diode (L.E.D.) indicator2) “FOR” (Forward) output L.E.D. indicator3) “Rev” (Reverse) output L.E.D. indicator4) “Air

Page 48 - SECTION VII

48e. Open main door. The dryer must stop and ALL indicator dots of the microprocessor controller (computer)light emitting diode (L.E.D.) display must

Page 49

ADC 112247 1- 02/06/97-10 2- 06/13/97-25 3* 05/15/98-254* 08/03/98-50 5* 11/04/98-25 6- 08/31/99-257- 09/28/00-10 8* 10/19/00-25

Page 50 - SECTION VIII

SECTION VIROUTINE MAINTENANCE ...41A. Cleaning ...

Page 51

3SECTION IIMPORTANT INFORMATIONA. RECEIVING and HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Page 52

4B. SAFETY PRECAUTIONSWARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preven

Page 53 - 7- 09/28/00-10 8* 10/19/00-25

5WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create afire hazard. WARNING: DO NOT use heat for drying articles tha

Comments to this Manuals