American Dryer Corp. Gas/Steam Models ML-82 Operator's Manual

Browse online or download Operator's Manual for Electric laundry dryers American Dryer Corp. Gas/Steam Models ML-82. American Dryer Corp. Gas/Steam Models ML-82 Operator`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ML-82
Installation/Operator’s Manual
101498GS/cj
ADC Part No. 113051
(Gas/Steam Models)
For replacement parts, contact the distributor from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
E-mail: techsupport@amdry.com
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimumle risque
dincendie ou dexplosion pour ou éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser dessence ni
dautres vapeurs ou liquides inflammables dans
le voisinagede cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter dallumer dappareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment vous vous trouvez..
* Évacuez la pièce le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz appelez le service des incendies.
Línstallation et lentretien doivent être assurés
par un installateur ou un service dentretien
qualiifié ou par le fournisseur de gaz.
Page view 0
1 2 3 4 5 6 ... 50 51

Summary of Contents

Page 1 - (Gas/Steam Models)

ML-82Installation/Operator’s Manual101498GS/cjADC Part No. 113051(Gas/Steam Models)For replacement parts, contact the distributor from which the drye

Page 2 - Important

6Specifications*ML-82(Gas and Steam ONLY)NOTE: ADC reserves the right to make changes in specifications at any time, without notice orobligation.

Page 3 - IMPORTANT

7B. COMPONENT IDENTIFICATION1. Dryer Front ViewIllus. No. Description1 Controls2 Control (top access) Door Assembly3 Main Door Assembly4 Lint Compar

Page 4 - FOR YOUR SAFETY

82. Dryer Rear ViewIllus. No. Description1 Heating Unit2 1/8" Compressed Air Supply Inlet(behind Electric Service Relay Box for Steam Models ONL

Page 5 - Table of Contents

9SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Page 6

10B. UNPACKING/SETTING UPRemove protective shipping material (i.e., plastic wrap, and optional shipping box) from dryer.IMPORTANT: Dryer must be tran

Page 7 - SECTION I

11NOTE: Allowances must be made for opening the control door.Dryers may positioned side wall to side wall. However, a 1/16" minimum allowance

Page 8

12IMPORTANT: Even though a minimum of only 12 inches is required, 18 inches or more issuggested. The additional clearance is advantageous for ease of

Page 9 - SECTION II

13To compensate for the use of registers or louvers used over the openings, this makeup air must be increased byapproximately thirty-three percent (33

Page 10 - Specifications*

14ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructionswhich will collect lint. When adding ducts,

Page 11 - B. COMPONENT IDENTIFICATION

152. Single Dryer VentingWhere possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct shouldbe laid out in suc

Page 12

Retain This Manual In A Safe Place For Future ReferenceReplacement parts can be obtained from your distributor or the ADC factory. When

Page 13 - SECTION III

16IMPORTANT: For extended duct work runs, the cross section area of the duct work can only beincreased to an extent. When the duct work approaches th

Page 14 - B. UNPACKING/SETTING UP

17IMPORTANT: Exhaust back pressure measured by a manometer at each dryer exhaust duct area shouldnot exceed .3" of water column.The duct work sho

Page 16 - D. FRESH AIR SUPPLY

19F. ELECTRICAL INFORMATION1. Electrical RequirementsIt is your responsibility to have ALL electrical connections made by a properly licensed and co

Page 17 - E. EXHAUST REQUIREMENTS

202. Electrical Service SpecificationsIMPORTANT: The dryer must be connected to the electric supply shown on the data label thatis affixed to the back

Page 18

213. Electrical ConnectionsNOTE: A wire diagram is located in the front electrical control box for connection data.a. GAS MODELS and STEAM MODELS ONL

Page 19

22G. GAS INFORMATIONIt is your responsibility to have all plumbing connections made by a qualified professional to assure the gasplumbing installatio

Page 20

23a. Gas Connections:Inlet connection 1 inch N.P.T.Inlet supply size 1 inch N.P.T. (minimum)Btu/hr input (per dryer) 270,0001.Natural GasRegulation is

Page 21

243. PIPING AND CONNECTIONSALL components and materials must conform to national fuel gas code specifications. It is important thatgas pressure regul

Page 23 - F. ELECTRICAL INFORMATION

IMPORTANTYOU MUST DISCONNECT and LOCKOUT THE ELECTRICSUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANYCOVERS or GUARDS ARE REMOVED FROM

Page 24 - MLS-82 (Steam)

26H. STEAM INFORMATIONIt is your responsibility to have all steam plumbing connections made by a qualified professional to assure that theinstallation

Page 25

27d. Shut-off valves for each dryer should be installed in the supply, return, and drip trap return lines. This willallow the dryer to be isolated fr

Page 26 - Natural Liquid Propane

283. STEAM DAMPER AIR SYSTEM CONNECTIONSThe MLS-82 is manufactured with a pneumatic (piston) damper system which requires an external supply ofcompres

Page 27

295. STEAM DAMPER AIR PISTON (FLOW CONTROL) OPERATION ADJUSTMENTAlthough the damper operation was tested and adjusted prior to shipping at 80 psi, ste

Page 28

30I. PREPARATION FOR OPERATION/START-UPThe following items should be checked before attempting to operate the dryer:1. Read ALL "CAUTION,"

Page 29

31J. PREOPERATIONAL TESTSALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational testshould be performed

Page 30 - Minimum 100 psig*

32Electrically Heated Dryersa. Check to insure that electric oven/contactor assembly is activating.4. Make a complete operational check of ALL safety

Page 31

338. REVERSING MODELS ONLY - basket (tumbler) dryer should never be operated with less than a 30 lb.load (dry weight). The size of the load will affec

Page 32 - Maximum Supply 90 psi

34L. SHUT DOWN INSTRUCTIONSIf the dryer is to be shut down (taken out of service) for a period of time, the following must be performed:1. Discontinu

Page 33

35SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. Ifs

Page 34

FOR YOUR SAFETYDO NOT DRY MOP HEADS IN THE DRYER.DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.WARNINGUNDER NO CIRCUMSTANCES should the door

Page 35 - Steam Dryers

36SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARD(S)1. Before any dryer leaves the ADC factory test area, a warranty card (ADC Part No. 1122

Page 36 - Electrically Heated Dryers

372. Each part must be tagged with the following information:a. Model and serial numbers of the dryer from which part was removed.b. Nature of failure

Page 37 - 1. To start the dryer:

38SECTION VIROUTINE MAINTENANCEA. CLEANINGA program or schedule should be established for periodic inspection, cleaning, and removal of lint from va

Page 38 - L. SHUT DOWN INSTRUCTIONS

39STEAM DRYERSClean the steam coil fins. Suggest using compressed air and a vacuum cleaner with brush attachment.NOTE: When cleaning steam coil fins,

Page 39 - SECTION IV

40C. LUBRICATION1. Impellor (fan) shaft bearing must be lubricated every three (3) months.2. The motor bearing, idler bearings, and tumbler bearings

Page 40 - SECTION V

41SECTION VIIPROCEDURE FOR FUNCTIONAL CHECK OFREPLACEMENT COMPONENTS1. Microprocessor (computer) Boarda. Upon completing installation of the replace

Page 41

42Verify that the motor(s) heat, and door indicator lights on the back side of the microprocessor(computer) board are lit. (refer to the illustration

Page 42 - SECTION VI

43 d. Open main door. The dryer must stop and ALL output indicator lights on the back side of the micro- processor (computer) board must go out.

Page 43

44SECTION VIIIREVERSING TIMER SPIN/DWELLADJUSTMENTSDual timer models with "reversing option" have an electric reversing timer in the electr

Page 44 - D. LINT DRAWER REMOVAL

45SECTION IXTECHNICAL INFORMATIONA. DATA LABELContact American Dryer CorporationWhen contacting American Dryer Corporation certain information is r

Page 45 - SECTION VII

Table of ContentsSECTION IIMPORTANT INFORMATION ... 3A. Receiving and

Page 46

46THE DATA LABEL1. MODEL DRYERThe model number is an ADC number which describes the size of the dryer and thetype of heat (gas, electric, or steam).2.

Page 47

ADC 113051 1- 11/03/98-15 2- 12/08/98-5 3- 02/01/99-54* 03/25/99-50 5- 05/25/99-100 6* 09/21/99-1007* 02/24/00-20 8- 02/25/00-150

Page 48 - SECTION VIII

SECTION VWARRANTY INFORMATION ... 36A. Returning Warranty Card(s) ...

Page 49 - SECTION IX

3SECTION IIMPORTANT INFORMATIONA. RECEIVING and HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners an

Page 50

4d. Clear the room, building, or area of ALL occupants.e. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier&a

Page 51

5BASKET (TUMBLER) DIAMETER 37" 94 cmBASKET (TUMBLER) DEPTH 36" 91.5 cmBASKET (TUMBLER) MOTOR 1/2 HP .373 kwBLOWER MOTOR 3 HP 2.238 kwD

Comments to this Manuals

No comments