Standard temperature air inlet [
Series IDF
]
IDF1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1, 22E, 37E, 55E, 75E, 120D, 150D, 190D, 240D, 370B
High temperature air inlet [
Series IDU
]
IDU3E, 4E, 6E, 8E, 11E, 15E1, 22E, 37E, 55E, 75E
Improved corrosion resistance
with the stainless steel heat exchanger
(IDF4E to 75E/IDU3E to 75E)
Zero ozone depletion potential
RefrigerantRefrigerant
Up to
%
Air flow
capacity
Air flow
capacity
Up to
%
Increased by Reduced by
Power
consumptionconsumption
Power
consumption
R134a (HFC)
R407C (HFC)
R134a (HFC)
R407C (HFC)
(SMC comparison) (SMC comparison)
Series IDF/IDU
Refrigerated Air Dryers
An air dryer removes the vapor from the moist compressed air delivered by the
compressor, and prevents it from causing the pneumatic equipment to fail.
Protect Pneumatic Equipment from Moisture!Protect Pneumatic Equipment from Moisture!
Effects of moisture on equipment
Decomposition of auto drain
caused by rusting inside pipes
Generation of water droplets
Malfunctioning of valves and
actuators caused by dripping grease
CAT.ES30-8F
241-IDFIDU-CT.qxd 11.1.12 5:03 PM Page 1
Page view 0
1 2 3 4 5 6 ... 48 49

Summary of Contents

Page 1 - Refrigerated Air Dryers

Standard temperature air inlet [Series IDF]IDF1E, 2E, 3E, 4E, 6E, 8E, 11E, 15E1, 22E, 37E, 55E, 75E, 120D, 150D, 190D, 240D, 370BHigh temperature air

Page 2 - The Importance of Dryers

ALKNMBQPE DF GHJCFGEDJHMNAKLCQPBModelIDF1EIDF2EIDF3EIDF4EIDF6EIDF8EIDF11EPort size(mm)Rc 3/8A226B410453455485C413473498568D69516731E101125 42F2702323

Page 3 - SMC Air Preparation Equipment

DimensionsIDF15E1380603165781014 x ø1330027031415Evaporation thermometerIlluminated switchVentilation directionVentilation direction(O.D. ø10, length

Page 4

How to OrderSizeSymbol22 kW37 kW55 kW75 kW22E37E55E75ECompressor size Note)VoltageSingle-phase200 VAC (50 Hz)200/220 VAC (60 Hz)20Three-phase200 VAC (

Page 5 - 3. Optional Accessories

Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure 20°C, relative humidity 65%] Note 2) Air flow capacity converted by

Page 6 - Model Selection

FDHNMCEBGAKPLJRAQGBEDFCPLKJHMNDimensionsIDF22E, 37EModelIDF22EIDF37EIDF55EIDF75EPort sizeR 1R 1 1/2R 2B775855855A290470C623800900D134128E405455F698868

Page 7

Refrigerant R407C (HFC) / R22Standard Temperature Air InletSeries IDF쏔D, B120D, 150D, 190D, 240D, 370B(Inlet air temp.: 40°C (120D, 150D, 190D, 240D),

Page 8

Standard SpecificationsWater-Cooled Condenser Specifications (IDF370B)Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressu

Page 9

DAGJBHIEFCDimensionsIDF120D, 150D, 190D, 240DIDF370BModel Inlet and outlet port∗ The auto drain is enclosed in the same shipping package as the main b

Page 10 - Series IDF

Refrigerant R134a (HFC)High Temperature Air InletSeries IDU쏔E3E, 4E, 6E, 8E, 11E, 15E1(Inlet air temperature: 55°C, Outlet air pressure dew point: 10°

Page 11

Applicable air compressor output (Reference)For screw type Compressed air5 to 800.15 to 1.02 to 40 (Relative humidity 85% or less)0.755321010 (100 VAC

Page 12

Refrigerated Air Dryers Series IDF/IDUCompressed air contains moisture (water vapor, droplets), oil, debris and other foreign matter. Filters and mis

Page 13

FGEDJHMNAKLCQPBMNQBCDFEGHALPDimensionsIDU3E to 6E[100 VAC specification]Power cable(Length: approx. 1.9 m)Air inletAir outletPort sizePort size[200 VA

Page 14

Refrigerant R407C (HFC)High Temperature Air InletSeries IDU쏔E22E, 37E, 55E, 75E(Inlet air temperature: 55°C, Outlet air pressure dew point: 10°C)How t

Page 15

Refrigeratedair dryerAuto drainJIS SymbolNote 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure 20°C, relative humidity 65

Page 16

GAPLJHCBEMNIDU22E to 75EDimensions13Terminal blockEvaporation thermometerIlluminated switch(O.D. ø10, length approx. 1 m)Drain tubeBall valveVentilati

Page 17

Cool compressed air outputOption symbolCool outlet air (10°C) can be supplied.The air flow with this option is smaller than that of the standard air d

Page 18 - Series IDU

Series IDF/IDUOptions 1-2Drainage including dust can also be exhausted.The float type auto drain used in the standard air dryer is replaced with a hea

Page 19

Series IDF/IDUOptions 2Refer to “How to Order” on pages 5, 9, 12, 15, 18 for optional models.The float type auto drain used in the standard air dryer

Page 20

ADCEBCEBDFASeries IDF/IDUOptions 3Refer to “How to Order” on pages 5, 9, 12, 15, 18 for optional models.With a circuit breakerOption symbolRThe air dr

Page 21

BDCABACABDSeries IDF/IDU EOptions 4Refer to “How to Order” on pages 5, 9, 12, 15, 18 for optional models.The option allows the connection of a power c

Page 22

Series IDF/IDUOptions 5Refer to “How to Order” on pages 5, 9, 12, 15, 18 for optional models.Drainage is discharged by controlling a solenoid valve wi

Page 23

쎲 For Screw Compressors (When an aftercooler is not installed, Refrigerated air dryer inlet temperature: ambient temperature +15°C, Membrane air dryer

Page 24 - Options 1

Note 1) When using a power transformer for the IDF1E to 15E1 and IDU3E to 15E1, select the air dryer of 100 V.Note 2) When using a power transformer f

Page 25 - Options 1-2

IDF FL D120Applicable air dryerSymbol120150190240Applicable air dryerIDF120D IDF150D IDF190D IDF240D IDU FL 210Applicable air dryerSymbol210211

Page 26 - Options 2

IDF BP[Bypass piping set (Rc, R thread)]302Applicable air dryerApplicable air dryerSymbol300301302303304316317318325IDU BP305Applicable air dr

Page 27 - Options 3

ABDCEABDEECFBDA240V200V230V220VINPUTIDF-TR 1Specifications/Dimensions[Separately installed power transformer]4 x FInput cable 2 mOUT PUTIN PUTPart n

Page 28 - Options 4

CBAEDACøGBTerminal block140110 15158190175 7.5ø26Cable hole1501304 x ø7250220152952502204 x ø10243Terminal block29027010Cable holeø3922029010295270243

Page 29 - Options 5

DCEFGABIDF4E to 75EIDU3E to 15E1[Dedicated base for separately installed power transformer]Applicableair dryerPart no. Applicable transformerReference

Page 30 - Optional Accessories

(IDF-FL200, 201) (IDF-FL202 to 214) (IDU-FL210 to 218)Part no.Applicable air dryerWeight (g)ABIDU8EIDU11EIDU15E1IDU22EIDU37EIDU55EIDU75E37537537536031

Page 31

Part no.IDF-BP303IDF-BP304IDF-BP316IDU-BP305IDU-BP306IDU-BP307Applicableair dryerIDF4EIDF6EIDF8EIDF11EIDF15E1IDU3EIDU4EIDU6EPort sizeRcABC314131175187

Page 32

DCAIDU8E to 15E1Part no.IDU-BP320IDU-BP322Applicableair dryerIDU8EIDU11EIDU15E1BPort sizeRc3/41A31792106877456477911291363.65.3C D EWeight(kg)(mm)Part

Page 33

CBFEG4 x ø13(A)(405)(134)(101)(290)(93)(D)Air outletPort sizeAir inletPort size4 x ø13 4 x ø13(109)240270(410) (71)275 85(587)(405)(134)(105)270300380

Page 34

P.5 to 8P.9 to 11P.12 to 14PageModel RefrigerantApplicable aircompressor (kW)50 Hz0.10.2 0.32 0.52 0.75 1.22 1.652.83.95.78.411.0 20.0 25.0 32

Page 35

ECDHI4 x ø13(F) (G)(B)(A)(J)Air inletPort sizeAir outletPort sizePart no.IDF-S0183IDF-S0202IDF-S0184IDF-S0185Applicable air dryerIDF6EIDF8EIDF11EIDF15

Page 36

ACB0.2454035302520151050EH0.30.40.50.60.70.81.61.01.40.1MPaABCGFD<How to calculate the amount of condensed water>Example) To obtain the amount o

Page 37

IDFIDU-F.qxd 10.6.18 11:58 AM Page 41

Page 38

1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.Since the product spec

Page 39

• Avoid locations where the air dryer will be in direct contact with wind and rain. (Avoid locations where relative humidity is 85% or more.)• Avoid e

Page 40

IDF55E, 75E• When tightening the inlet/outlet air piping, firmly hold the hexa-gonal parts of the port on the air dryer side or piping with a wrench o

Page 41 - Dew Point Conversion Chart

Series IDF/IDU Specific Product Precautions 3Be sure to read the below before handling. For Air Preparation Equipment Precautions, refer to “Handling

Page 42

IDFA3EIDFA4EIDFA6EIDFA8EIDFA11EIDFA15EIDFA22EIDFA37EIDFA55EIDFA75E 12 24 36 65 80120182273390660 15 31 46 83101152231347432720 17 34 50 9

Page 43 - Compliance Requirements

Membrane Air Dryer Series IDG(For use in cases where a power supply is not provided)Related ProductsDew point indicator for checking air drying condi

Page 44 - IDF/IDU

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPANPhone: 03-5207-8249 Fax: 03-5298-5362URL http://www.smcworld.com© 2010 SMC Co

Page 45

2. OptionsP.21P.22P.23P.24P.25PageDescriptionCool compressed air outputAnti-corrosive treatment for copper tubeModerate pressure specification (up to

Page 46

The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting air dryer. Select using the following proc

Page 47 - Overseas Standards

Data A: Inlet Air TemperatureCorrection FactorsData C: Outlet Air PressureDew PointData B: Ambient TemperatureData D: Inlet Air PressureData E: Air Fl

Page 48 - Related Products

How to OrderSizeSymbol 0.75 kW 1.5 kW 2.2 kW 3.7 kW 5.5 kW 7.5 kW11 kW15 kW1E2E3E4E6E8E11E15E1Compressor size Note)VoltageSingle-phase100 VAC (5

Page 49 - Safety Instructions

IDF1E IDF2E, 3ERefrigeratedair dryerAuto drainJIS SymbolHumid, hot air coming into the air dryer will be cooled down by a cooler (heat exchanger). Wat